RKO BOILER's YY(Q)W horizontal coil-type thermal oil heater delivers up to 320 C at low pressure on natural gas, LPG or diesel, backed by local service in Asia, Africa and the Middle East.
The YY(Q)W is a horizontal coil-type thermal oil boiler that heats a closed-loop oil to as high as 320 C while the system stays at low pressure. It fires on natural gas, LPG or diesel and is built by RKO BOILER in Zhengzhou, Henan, where we have manufactured industrial boilers since 1981. For plants in Asia, Africa and the Middle East that need high-temperature process heat without a high-pressure steam system, this model is a direct fit.
How the YY(Q)W Thermal Oil Heater Works
Thermal oil is circulated through a helical coil wrapped around the combustion chamber. The burner fires into the chamber, and hot flue gas travels the full length of the coil in two or three passes before leaving through the stack. Because the oil moves through the coil and absorbs heat along the way, it leaves the heater at the set temperature and returns cooler from the process, ready to be heated again.
The loop is closed and operates at low pressure, so the oil can reach temperatures far above the boiling point of water without the pressure vessel requirements of a steam boiler. A forced-circulation pump keeps flow steady, and the control system modulates the burner to hold the outlet temperature. The horizontal layout keeps the coil accessible for inspection and gives the unit a compact footprint for its capacity.
Key Specifications
| Parameter | YY(Q)W Series Data |
|---|---|
| Model range | YY(Q)W-350Y(Q) to YY(Q)W-7000Y(Q) |
| Rated thermal capacity | 350 kW to 7,000 kW (0.3 to 6.0 million kcal/h) |
| Design outlet temperature | Up to 320 C |
| Design pressure | Low pressure, normally 0.8 to 1.0 MPa |
| Fuel options | Natural gas, LPG, diesel (light oil) |
| Structure | Horizontal, three-pass coil type |
| Burner | Proportional modulating, automatic ignition |
| Thermal efficiency | Typically 90% or higher |
| Circulation | Forced circulation pump, closed loop |
Fuel and Capacity Range
The series spans 350 kW to 7,000 kW, which covers small process lines and larger multi-user loops. Each unit is configured at order for one fuel type: natural gas where a pipeline is available, LPG for sites on tanks or cylinders, or diesel for locations without a gas supply. The modulating burner trims output to match the load, so the heater does not cycle on and off at full fire during partial demand.
Because the loop is closed, oil consumption is limited to make-up for small losses, and the same charge circulates for long periods. In Asia, Africa and the Middle East, where fuel logistics vary widely between Luzon, Visayas and Mindanao, this flexibility lets a plant standardize on one heater design while choosing the fuel that is actually available on site.
Applications
The YY(Q)W suits processes that need steady heat between roughly 150 C and 320 C:
- Chemical and pharmaceutical reactors, distillation and drying
- Food processing: frying lines, baking ovens, rendering and sterilization
- Textile dyeing, printing and finishing
- Rubber, plastics and resin processing
- Building materials, asphalt and coating lines
- Plywood, board and wood drying
It is also a practical choice where a steam boiler would need a high-pressure system and dedicated operator attention. Explore the full thermal oil boiler range or see all RKO BOILER products.
Installation and Service in Asia, Africa and the Middle East
RKO BOILER supports Asia, Africa and the Middle Eastn projects from inquiry through commissioning. Our team reviews the heat load, temperature profile, fuel supply and site layout, then matches the model and coil configuration to the duty. We prepare the drawings and documentation needed for local permitting, and our engineers can travel to site for installation supervision, loop flushing, oil filling and start-up.
After handover, operators receive training on burner adjustment, temperature control and routine checks. Spare parts and technical support are arranged through our Asia, Africa and the Middle Eastn service channel, and our engineers respond to troubleshooting requests remotely or on site. To discuss a project, contact RKO BOILER with your capacity, temperature and fuel details.