The WDR electric heating steam boiler from RKO delivers 0.5–4 t/h of steam at 0.7–1.6 MPa with high automation and zero flue gas at the point of use. Learn how it works, its specifications and service in Asia, Africa and the Middle East.
The WDR electric heating steam boiler is a horizontal, fully packaged electric steam boiler produced by RKO for steam users who want clean, quiet, highly automated steam with no flue gas at the point of use. It covers 0.5–4 t/h and 0.7–1.6 MPa, making it suitable for small and mid-sized process loads in Asia, Africa and the Middle East. Because heat is generated by immersed electric heating elements rather than a burner, there is no fuel storage, no chimney and no combustion air requirement at the installation.
How the WDR Electric Heating Steam Boiler Works
The WDR is a horizontal shell boiler in which electric heating elements are inserted directly into the water space. A control cabinet stages the elements in groups, switching them on and off to match the actual steam demand, so output follows the load rather than running at a fixed rate. As steam is drawn off, feed water is added automatically and the water level is monitored continuously.
Steam pressure is regulated by a pressure controller that brings element groups in and out of service around the set point. Safety is handled by independent high-pressure and low-water protections, and the boiler is supplied as a packaged unit with the control panel, feed pump, valves and instruments mounted on the skid. This compact arrangement reduces site work and keeps the boiler room tidy.
For operators in Asia, Africa and the Middle East, the main practical difference from a fuel-fired boiler is that there is no burner to tune, no fuel line to maintain and no stack to route. Heat input is electrical, so the boiler is quiet in operation and emits no flue gas where the steam is used. Efficiency is high because the heating elements are immersed in water and the shell is insulated.
Key Specifications
| Item | WDR Series Data |
|---|---|
| Type | Horizontal electric heating steam boiler |
| Rated evaporation | 0.5–4 t/h |
| Rated steam pressure | 0.7–1.6 MPa |
| Steam temperature | Saturated, corresponding to rated pressure |
| Heat source | Electric heating elements immersed in the water space |
| Control | Automatic staged element control, pressure and water level regulation |
| Safety devices | High-pressure protection, low-water protection, overcurrent protection |
| Arrangement | Horizontal shell, packaged with control cabinet and feed pump |
| Fuel | None – electrically heated |
Exact dimensions, weights, electrical supply and element configuration are confirmed per order based on the required capacity and site conditions.
Fuel and Capacity Range
The WDR has no fuel requirement in the conventional sense: its energy input is electricity. Capacity runs from 0.5 to 4 t/h, with steam pressure from 0.7 to 1.6 MPa. Within this range the model is selected according to the peak steam load, the operating pressure and the electrical supply available at the site. Because the boiler is electrically heated, the capacity decision is closely tied to the site’s power supply; RKO reviews the electrical data together with the steam demand before confirming a configuration.
For sites where electricity is limited or where steam demand is larger, RKO can advise on alternative models from the wider product range; see the RKO product range or electric steam boilers for related options.
Applications
The WDR is well suited to processes that need clean steam and predictable control. Typical uses include:
- Food and beverage processing, including cooking, sterilization and cleaning
- Pharmaceutical and chemical process heating where flue gas at the point of use is undesirable
- Textile, garment and laundry operations requiring steady steam
- Small and mid-sized factories with limited boiler room space
- Buildings and facilities needing packaged, low-attention steam supply
In Asia, Africa and the Middle East, these loads are common in food plants, hospitals, hotels and light manufacturing, where the WDR’s automatic operation and compact footprint suit both new installations and replacements.
Installation and Service in Asia, Africa and the Middle East
The WDR arrives as a packaged unit, so installation mainly involves positioning the boiler, connecting the electrical supply, feed water, steam outlet and blowdown lines, and commissioning the controls. RKO provides installation guidance and commissioning support, and can work with the customer’s electrical contractor on supply and protection requirements.
Service in Asia, Africa and the Middle East is supported through RKO’s local channels, covering routine inspection, element and control checks, water treatment advice and spare parts. Because water quality strongly affects element life, RKO recommends a feed water treatment plan and regular blowdown as part of normal operation. To discuss a project or request a quotation, contact the RKO team.