Skip to content
RKO BOILER

WNS Ultra-Low-NOx Gas Fired Boiler

RKO's WNS ultra-low-NOx gas fired boiler delivers under 30 mg/Nm3 NOx with flue gas recirculation. Packaged 1-20 t/h, built for Asia, Africa and the Middle Eastn industry.

Home // Product models // WNS Ultra-Low-NOx Gas Fired Boiler

RKO's WNS ultra-low-NOx gas fired boiler delivers under 30 mg/Nm3 NOx with flue gas recirculation. Packaged 1-20 t/h, built for Asia, Africa and the Middle Eastn industry.

RKO’s WNS ultra-low-NOx gas fired boiler is a packaged fire-tube unit that uses flue gas recirculation (FGR) to hold nitrogen oxide emissions below 30 mg/Nm3. It is available from 1 to 20 t/h and is engineered for natural gas, LPG, and light oil firing. For Asia, Africa and the Middle Eastn plants facing stricter air-quality expectations, this model combines low emissions with the simple installation and maintenance of a shop-assembled package.

How the WNS Ultra-Low-NOx Boiler Works

The WNS is a three-pass wet-back fire-tube boiler. Fuel burns in a fully submerged furnace, and hot gases reverse through second- and third-pass tube bundles before leaving the stack. The low-NOx result comes from the burner and furnace working together: a flue gas recirculation line draws a portion of cooled exhaust back into the combustion air, lowering flame temperature and suppressing thermal NOx formation. The burner is matched to the furnace volume so the flame stays stable and complete combustion is maintained across the turndown range.

All parts are mounted on a single skid: burner, feedwater pump, control panel, valves, and safety interlocks. The boiler arrives at site as a tested package, which shortens erection and commissioning compared with field-erected designs.

Key Specifications

Parameter WNS Ultra-Low-NOx Series
Model range WNS1 to WNS20
Rated capacity 1–20 t/h (0.7–14 MW)
Design pressure 1.0, 1.25, 1.6 MPa (standard)
Steam temperature Saturated, up to 204°C at 1.6 MPa
Feedwater temperature 20°C (standard), 104°C (economizer option)
Fuel Natural gas, LPG, light oil (dual-fuel option)
NOx emission <30 mg/Nm3 (FGR, gas firing)
Combustion efficiency Up to 92% (higher with economizer)
Burner turndown Up to 5:1
Control system PLC-based, automatic modulating
Mounting Shop-assembled package, skid-mounted

Fuel and Capacity Range

The WNS series covers 1 to 20 t/h in single-boiler increments. Smaller sizes suit batch processes and packaged plants, while larger units serve continuous steam demand. The standard burner handles natural gas and LPG; a dual-fuel option allows changeover to light oil without major modification. Flue gas recirculation is used on gas firing to achieve the sub-30 mg/Nm3 NOx level. Capacity and pressure combinations are selected per project, and RKO confirms the final configuration against your load profile.

Applications

The boiler is used where clean steam and low emissions matter:

  • Food and beverage processing (sterilization, cooking, concentration)
  • Pharmaceutical and chemical plants requiring stable process steam
  • Textile dyeing and finishing
  • Paper and packaging mills
  • Commercial buildings, hospitals, and district heating

Because the package is compact, it fits well in plants with limited boiler-house space or where a replacement must be completed quickly.

Installation and Service in Asia, Africa and the Middle East

RKO has served Asia, Africa and the Middle Eastn industry since its founding in 1981. For WNS projects, we provide foundation and piping drawings, a commissioning checklist, and operator training. Our regional service team supports start-up and scheduled maintenance, and spare parts are available through our Asia, Africa and the Middle Eastn channel. We also assist with local boiler registration and inspection documentation where required. To discuss site conditions, fuel supply, and delivery scheduling, please contact our team.

Frequently Asked Questions

What NOx level can the WNS boiler achieve in Asia, Africa and the Middle East?

With flue gas recirculation and gas firing, the WNS is designed for NOx below 30 mg/Nm3. Actual results depend on fuel composition and load; RKO verifies performance during commissioning.

Can the boiler burn LPG or diesel as well as natural gas?

Yes. The standard burner is set for natural gas or LPG, and a dual-fuel option allows light oil firing. Fuel changeover is handled through the burner management system.

What capacity range is available for Asia, Africa and the Middle Eastn plants?

The WNS series covers 1 to 20 t/h. We size the boiler to your steam load and pressure requirement, and can supply an economizer to improve efficiency.

Does RKO provide installation and after-sales support in Asia, Africa and the Middle East?

Yes. RKO supplies installation drawings, commissioning support, operator training, and spare parts through our Asia, Africa and the Middle Eastn service network. Visit our products page to see the full range, including gas and oil fired boilers.

Next step

Tell us about your steam demand

Share your process load, working pressure, fuel availability, and site location. We will reply with a model shortlist and capacity range.

WhatsApp Email Contact